Buy nowYour basket (0)

Blue Marine Installation Guide — Revised Preview

BLUE MARINE · TECHNICAL GUIDANCE

Marine Air Conditioning Installation Guide

Technical guidance for selecting and installing Blue Marine SC Series self-contained marine air conditioning systems.

01 / INSTALLATION GUIDE

Typical System Installation

A typical SC Series installation includes a seawater cooling circuit, cabin air distribution, electrical connections and independent condensate drainage.

Blue Marine typical installation diagram

02 / INSTALLATION GUIDE

Calculate Your Cooling Requirements

Estimate cooling capacity from cabin dimensions, solar exposure and operating climate. Confirm final system sizing with your installer.

Open the existing interactive BTU calculator →

Calculator opens separately in this layout preview.

03 / INSTALLATION GUIDE

Airflow & Ducting Requirements

Maintain unrestricted return airflow and correctly sized, insulated supply ducting. Avoid sharp bends and observe the maximum total duct length of 4 m.

Model Airflow Duct diameter Seawater flow
BM08SC 500 m³/h 100 mm 600 L/h
BM12SC 600 m³/h 125 mm 900 L/h
BM16SC 730 m³/h 150 mm 1250 L/h
BM24SC 1200 m³/h 200 mm 1800 L/h
BM30SC 1350 m³/h 200 mm 2200 L/h

04 / INSTALLATION GUIDE

Seawater Pump Selection

Select the seawater pump for the required flow at the actual working head, allowing for pipework, fittings, strainer and condenser resistance.

05 / INSTALLATION GUIDE

Shared Seawater Pump Systems

A common pump may supply multiple units through a correctly sized manifold. Use a compatible relay module to isolate each unit's pump demand signal.

06 / INSTALLATION GUIDE

Installation & Commissioning

Provide secure mounting, access for maintenance, effective condensate drainage and suitable electrical protection. A qualified marine HVAC engineer should commission the installation.